KVM Host: Hardware RAID with cache + BBU vs. Linux Software RAID with LVM writeback cache and UPS

· 52CE 我爱测

I want to set up a RAID 5 with 3x1TB drives on a Linux KVM-Host. The RAID will be used as LVM thin storage for VM disks. There has already been much discussion on hardware raid vs software [1]. According to this discussion one sh…

问题原文

原帖链接 · c0d3z3r0 · CC BY-SA 3.0

I want to set up a RAID 5 with 3x1TB drives on a Linux KVM-Host. The RAID will be used as LVM thin storage for VM disks.

There has already been much discussion on hardware raid vs software [1]. According to this discussion one should not use software raid but hardware raid with cache and BBU for VM disk storage because of the better write performance.

What I would like to know is if the following setup would be comparable to a hardware raid with cache and BBU (e.g. HP P410 512 MB + BBU) in terms of read/write performance and data safety:

  • Linux Software RAID / mdadm RAID 5
  • LVM writeback cache on a 512 MB ram disk
  • Host backed by UPS to prevent data loss like the BBU on hw raid

[1] Software vs hardware RAID performance and cache usage

已采纳解答

原帖链接 · BaronSamedi1958 · CC BY-SA 3.0

None from above! You really need to look at ZFS on Linux.

http://zfsonlinux.org

https://www.reddit.com/r/zfs/comments/514k2r/kvm_zfs_best_practices/

Perfect discussion, tons of links.

摘自公开归档,保留原文语言,版式经整理,外部媒体与邮箱地址已移除。