大网数据广告活动
服务器运维问答

LSI Megaraid alarm - clearing hotspare

· 52CE 我爱测

I have several Supermicro servers with LSI Megaraid controllers, 9266-8i. One recently lost a drive; I replaced it as usual, but it is still beeping on reboot. It is set up as RAID 10 + hotspare. MegaCli64 -AdpEventLog -GetEvents…

问题原文

原帖链接 · Bob · CC BY-SA 3.0

I have several Supermicro servers with LSI Megaraid controllers, 9266-8i. One recently lost a drive; I replaced it as usual, but it is still beeping on reboot. It is set up as RAID 10 + hotspare.

MegaCli64 -AdpEventLog -GetEvents -f events.log -aALL && cat events.log shows me:

Event Description: Global Hot Spare created on PD 08(e0xfc/s0) (global,rev)
Event Description: Reminder: Potential non-optimal configuration due to drive PD
                    08(e0xfc/s0) commissioned as emergency spare

Since the beep pattern is 1 second on, 3 seconds off, which is the code for "SPEAKER_HOTSPARE_ENTRY - A hot spare drive has completed the rebuild process and has been brought into the array", I assume this is the root of the problem. I have updated to the latest firmware, since the release notes mentioned the "Potential non-optimal configuration" message, but no change.

Anyone have an idea on how to clear this?

社区高分解答

原帖链接 · eal · CC BY-SA 3.0

Source: IBM tip H206526

There is no functional impact. To prevent the message from appearing in the system event logs:

  • Open MegaRAID Storage Manager.
  • Select Tools --> Monitor Configure Alerts.
  • Select Change Individual Events.
  • Highlight event ID 406.
  • Deselect the System log check box.

摘自公开归档,保留原文语言,版式经整理,外部媒体与邮箱地址已移除。

资料来源与适用范围

资料来源
Server Fault
适用范围
以原帖系统、软件版本与发布日期为准(2014-12-11)
内容语言
中文;命令、路径和错误标识保留技术原文
本地收录日期
2026-11-15
授权说明
CC BY-SA 3.0

正文与所需资源由本站本地存储。查看来源及更新记录 ↗

请按适用版本和实际日志确认原因;本站没有对每一种系统或设备逐项执行文中的操作。