大网数据广告活动
服务器运维问答

ZFS performance: Extreme low write speed

· 52CE 我爱测

I am running a small home server. The specs are: CPU: AMD Ryzen 5 2600 RAM: 32 GB ECC System drive: 128GB NVMe SSD Data drives: 3x 4 TB Seagate Barracuda HDD The server runs some applications like Nextcloud or Gitea and I want to…

问题原文

原帖链接 · Philip Szalla · CC BY-SA 4.0

I am running a small home server. The specs are:

  • CPU: AMD Ryzen 5 2600
  • RAM: 32 GB ECC
  • System drive: 128GB NVMe SSD
  • Data drives: 3x 4 TB Seagate Barracuda HDD

The server runs some applications like Nextcloud or Gitea and I want to run 1-2 VMs on it. So there are some web applications, databases and VMs.

The applications and qcow2 images are stored on a raidz1 pool:

$ sudo zpool status
  pool: tank
 state: ONLINE
config:

        NAME        STATE     READ WRITE CKSUM
        tank        ONLINE       0     0     0
          raidz1-0  ONLINE       0     0     0
            sdb     ONLINE       0     0     0
            sdc     ONLINE       0     0     0
            sdd     ONLINE       0     0     0

errors: No known data errors

When I used the applications in the first weeks, I experienced no problems. But since a few weeks I realized extremly low write speeds. The nextcloud instance is not very fast and when I try to start a fresh VM with Windows 10 it needs about 5 Minutes to get to the login screen.

I did some performance testing using fio and got following results:

Test IOPS Bandwith (KiB/s)
random read 37,800 148,000
random write 31 127
sequential read 72,100 282,000
sequential write 33 134

I did some research before posting here and read that I should add a SLOG to the zfs pool for better performance with databases and VMs. But that's no option at the moment. I need to get christmas gifts first :D

But even without a SLOG I don't think these figures are correct :(

Does anyone have an idea? :)

已采纳解答

原帖链接 · Philip Szalla · CC BY-SA 4.0

I found the problem by myself.

I saw an article mentioning CMR (conventional magnetic recording) and SMR (shingled magnetic recording), the latter of which offers decreased write performance. I checked my drives and I realized that I accidentally bought hard drives with SMR :(

I will keep a mirror pool until I replaced the drives with new CMR drives. When I have the new drive I will also use a mirror pool.

Thank you all!