Drive allocation in a RAID 50 array on a HPE DL380 G9

· 52CE 我爱测

I have a DL380 G9 with 12x8TB 3.5" disks: | 1 | 4 | 7 | 10 | | 2 | 5 | 8 | 11 | | 3 | 6 | 9 | 12 | In the Smart Array Controller GUI, if I select all 12 disks and assign them to a RAID 50 array, how will the controller divide the…

问题原文

原帖链接 · rst-2cv · CC BY-SA 4.0

I have a DL380 G9 with 12x8TB 3.5" disks:

| 1 | 4 | 7 | 10 |
| 2 | 5 | 8 | 11 |
| 3 | 6 | 9 | 12 |

In the Smart Array Controller GUI, if I select all 12 disks and assign them to a RAID 50 array, how will the controller divide the disks for the RAID 5 arrays?

Will drives 1-6 and 7-12 inclusive be in two separate RAID 5 arrays, striped for RAID 0? Or will drives 1-3, 4-6, 7-9, and 10-12 be in four separate RAID 5 arrays striped for RAID 0?

If it's the former by default, is it possible to manually configure the array to the latter?

已采纳解答

原帖链接 · batistuta09 · CC BY-SA 4.0

The number of RAID5 sets for RAID0 should be able to configure in raid utility. In your case you can select 2 (6 disks in RAID5), 3 (4 disks in RAID5) or 4(3 disks in RAID5). From perfromance and capacity perspective - 2 RAID5 sets is most preferable in your case.

P.S. RAID50 tolerates only one disk failure (second disk failure from same RAID5 set will bring whole system down)

摘自公开归档,保留原文语言,版式经整理,外部媒体与邮箱地址已移除。