False alarm on zabbix trigger in web scenario

· 52CE 我爱测

I have a website whose running on Apache Server. I want recieve a notification every time when a web site falling down.I created a trigger: {Zabbix server:web.test.fail[http:example.com].sum(#6)}>0 But website running not well an…

问题原文

原帖链接 · kiryushinsa · CC BY-SA 4.0

I have a website whose running on Apache Server. I want recieve a notification every time when a web site falling down.I created a trigger:

{Zabbix server:web.test.fail[http:example.com].sum(#6)}>0

But website running not well and i receive a error every 6 hours or 30 minutes.

How writing a trigger which send me a notification after 12 minutes (for example) error site?

I just want to my trigger didn't catch a small error of web site. Only global crash.

已采纳解答

原帖链接 · Antonnvk · CC BY-SA 4.0

You can use the min / max function for this purpose.

For example

{Zabbix server:web.test.fail[http:example.com].min(12m)}>0

The trigger will work if the site is unavailable within 12 minutes.

And with this example

{Zabbix server:web.test.fail[http:example.com].max(12m)}<1

You can return the trigger to working condition if the site is available for more than 12 minutes

https://www.zabbix.com/documentation/4.2/ru/manual/appendix/triggers/functions