大网数据广告活动
服务器运维问答

RAID-5 inoperable, but no disk failure

· 52CE 我爱测

Inheritted a system with a 3ware LSI 9750-8i having five disks and RAID-5. I see a message about " RAID-5 INOPERABLE " for u1 but see no disk failure for the only disk (p1) in the unit. Unit UnitType Status %RCmpl %V/I/M Stripe S…

问题原文

原帖链接 · G. D'Seas · CC BY-SA 4.0

Inheritted a system with a 3ware LSI 9750-8i having five disks and RAID-5. I see a message about "RAID-5 INOPERABLE" for u1 but see no disk failure for the only disk (p1) in the unit.

Unit  UnitType  Status         %RCmpl  %V/I/M  Stripe  Size(GB)  Cache  AVrfy
------------------------------------------------------------------------------
u0    RAID-5    OK             -       -       256K    5587.9    RiW    ON
u1    RAID-5    INOPERABLE     -       -       256K    5587.9    Ri     ON

VPort Status         Unit Size      Type  Phy Encl-Slot    Model
------------------------------------------------------------------------------
p0    OK             u0   1.82 TB   SATA  0   -            WDC WD2000FYYZ-01UL
p1    OK             u1   1.82 TB   SATA  1   -            WDC WD2003FYYS-02W0
p2    OK             u0   1.82 TB   SATA  2   -            WDC WD2003FYYS-02W0
p3    OK             u0   1.82 TB   SATA  3   -            WDC WD2003FYYS-02W0
p4    OK             u0   1.82 TB   SATA  4   -            WDC WD2000FYYZ-01UL

Name  OnlineState  BBUReady  Status    Volt     Temp     Hours  LastCapTest
---------------------------------------------------------------------------
bbu   On           Yes       OK        OK       OK       127    xx-xxx-xxxx

I don't quite get what is going on here and I am not seeing any errors in the logs or the operation of the system either.

I suspect that u1/p1 is the spare. Am I right? Do I need to replace the p1 disk and rebuild the u1 array? Or just try to rebuild the u1 array?

The User Guide I have, is silent about what to do in this case.

已采纳解答

原帖链接 · shodanshok · CC BY-SA 4.0

I think the u1 disk is a leftover from another RAID5 array, so the controller detect it but can clearly not activate it. To use that disk as a spare, you need to first clear the RAID config on u1 disk and then re-add that disk to the array (as a spare).

Before doing anything, be sure to study the controller docs and to have current, valid backups

摘自公开归档,保留原文语言,版式经整理,外部媒体与邮箱地址已移除。

资料来源与适用范围

资料来源
Server Fault
适用范围
以原帖系统、软件版本与发布日期为准(2020-12-10)
内容语言
中文;命令、路径和错误标识保留技术原文
本地收录日期
2026-11-15
授权说明
CC BY-SA 4.0

正文与所需资源由本站本地存储。查看来源及更新记录 ↗

请按适用版本和实际日志确认原因;本站没有对每一种系统或设备逐项执行文中的操作。