This article helps you resolve the problem where Application Initialization module isn't working for web site configured to require Secure Sockets Layer (SSL).
Original product version: ASP.NET
Original KB number: 2843964
Symptoms
Application Initialization module formerly known as Application Warmup isn't working for web site configured to require SSL.
Cause
This behavior is by design.
The warm-up module sends the request using Hypertext Transfer Protocol (HTTP) and not with Hypertext Transfer Protocol Secure (HTTPS). The workaround suggested will allow HTTP requests to localhost from warm-up module but it redirects to the HTTPS for the rest of the requests so by design here means that the warm-up module makes requests over HTTP.
Resolution
To work around this limitation, you may consider enabling HTTP (unchecked the Require SSL setting under IIS Manager > SSL Settings) and use a URL Rewrite rule to redirect HTTP requests to HTTPS with the exception of the request coming from the warm-up module:
<rewrite>
<rules>
<rule name="No redirect on warmup request (request from localhost with warmup user agent)"
stopProcessing="true">
<match url=".*" />
<conditions>
<add input="{HTTP_HOST}" pattern="localhost" />
<add input="{HTTP_USER_AGENT}" pattern="Initialization" />
</conditions>
<action type="Rewrite" url="{URL}" />
</rule>
<rule name="HTTP to HTTPS redirect for all requests" stopProcessing="true">
<match url="(.*)" />
<conditions>
<add input="{HTTPS}" pattern="off" />
</conditions>
<action type="Redirect" url="https://{HTTP_HOST}/{R:1}" />
</rule>
</rules>
</rewrite>
Source: Microsoft Learn / IT Pro troubleshooting by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.