大网数据广告活动
性能与资源

Changing ATA drive setting causes reboot loop

· 52CE 我爱测

Help fix the reboot loop issue that occurs when you change the ATA drive setting in System Bios.

This article provides a solution to a reboot loop issue that's caused by changing the ATA Drive setting.

Applies to:   Windows 8
Original KB number:   2751461

Symptoms

Consider the following scenario:

  • The BIOS setting for the drive is set to ATA Mode.
  • Install or upgrade the system to Windows 8.
  • You boot into the BIOS and changed the ATA setting from ATA Mode to AHCI Mode pressed enter to accept the change.
  • You click Yes to the Warning about the detected mode change on the embedded ATA controller.
  • You restart the computer and boot normally. In this scenario, during the system boot when Windows tries to start, you will receive an error with regards to a system failure. The system will be stuck in a reboot loop.

Cause

This is due to changes in Windows 8 PnP in which Boot Start Drivers are not installed by default.

Resolution

In order to correct this issue, please walk through the following steps:

  1. Power down or restart the computer and enter the system BIOS.

  2. Change the ATA Drive setting back to ATA Mode, press enter to accept the change and restart the computer.

  3. Click Yes to the Warning about the detected mode change on the embedded ATA controller.

  4. The system will boot normally to the Modern App Start Menu.

    [!NOTE] Be sure you know the Local Admin account and password and are able to boot successfully before proceeding.

  5. Open an elevated command prompt and run the following command to enable SafeMode boot: bcdedit /set {current} safeboot minimal

  6. Restart the computer and boot to the system BIOS.

  7. Change the ATA Drive setting from ATA Mode to AHCI Mode, press enter to accept the change.

  8. Click Yes to the Warning about the detected mode change on the embedded ATA controller.

  9. The system will boot normally to the Modern App Start Menu in SafeMode.

  10. Open an elevated command prompt and run the following command to remove the SafeMode boot option:

    bcdedit /deletevalue {current} safeboot
    
  11. Restart the computer and boot normally, the system will boot successfully to the Modern App Start Menu.

More information

For additional information on Windows 7 in a similar scenario, please see the following KB.

Error message when you start a Windows 7 or Windows Vista-based computer after you change the SATA mode of the boot drive: "STOP 0x0000007B INACCESSABLE_BOOT_DEVICE"https://support.microsoft.com/kb/922976

Source: Microsoft Learn / IT Pro troubleshooting by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.

资料来源与适用范围

资料来源
Microsoft Learn / IT Pro troubleshooting
适用范围
- Supported versions of Windows Client · Source date 02/12/2026
内容语言
中文;命令、路径和错误标识保留技术原文
本地收录日期
2026-11-15
授权说明
CC BY 4.0 (documentation), MIT (code samples)