大网数据广告活动
域与目录服务

W32time settings fail when starting Windows Time Service

· 52CE 我爱测

Fixes an issue where the NTP client doesn't synchronize time at the SpecialPollInterval period as expected.

This article helps fix an issue where the NTP client doesn't synchronize time at the SpecialPollInterval period as expected.

Original KB number:   3205089

Symptoms

Assume that you modify W32time settings to always run and that one of the following conditions is true:

  • You use the default workstation settings.
  • You use custom NTP synchronization settings with a large SpecialPollInterval setting value.

In this scenario, the NTP client doesn't synchronize time at the SpecialPollInterval period as expected.

Cause

Because of the way that the Windows Time Service handles large SpecialPollInterval values, time may be synchronized from the NTP server at longer intervals than expected.

Resolution

Workaround 1

Specify a smaller SpecialPollInterval value than the default value. The default values are as follows:

MinPollInterval = 0xA (== 2^10 seconds == 1024 seconds)
MaxPollInterval = 0xF (== 2^15 seconds == 32768 seconds)
SpecialPollInterval = 604800 seconds

Specify a SpecialPollInterval value that falls between the MinPollInterval and MaxPollInterval. An example value is 3600 seconds (== 1 hour).

To configure W32time with the new setting, follow these steps:

  1. Start Registry Editor.

  2. Change the value of the following registry key:

    HKEY_LOCAL_MACHINE \SYSTEM\CurrentControlSet\Services\W32Time\TimeProviders\NtpClient

    Value name: SpecialPollInterval
    Default: 604800
    Modified value: 3600

  3. Restart the Windows Time Service, or run the following command to signal W32time about the modified configuration:

    w32tm /config /update  
    

Workaround 2

Use the built-in poll interval adjustments based on MinPollInterval, MaxPollInterval instead of using SpecialPollInterval. This built-in tool automatically adjusts the polling interval from MinPollInterval all the way up to MaxPollInterval if the client machine keeps fairly accurate time. You need only modify a flag in the NtpServer configuration in order to switch from SpecialPollInterval to the automatic poll interval, as follows:

  1. Start Registry Editor.

  2. Change the value of the following registry key:

    HKEY_LOCAL_MACHINE \SYSTEM\CurrentControlSet\Services\W32Time\Parameters

    Value name: NtpServer
    Default value: time.windows.com, 0x9
    Modified value: time.windows.com, 0x8

  3. Restart the Windows Time service, or run the following command:

    w32tm /config /update  
    

Source: Microsoft Learn / IT Pro troubleshooting by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.

资料来源与适用范围

资料来源
Microsoft Learn / IT Pro troubleshooting
适用范围
- Supported versions of Windows Server · Source date 02/12/2026