Hyper-V Time Synchronization can't correct system clock

· 52CE 我爱测

Discusses an issue in which The Hyper-V Time Synchronization Service won't correct the system clock in the virtual machine if the system clock in the VM is running more than five seconds ahead of the system clock on the host machine.

Original KB number:   2618634

Symptoms

The Hyper-V Time Synchronization Service won't correct the system clock in the virtual machine (VM), if the system clock in the VM is running more than five seconds ahead of the system clock on the host machine.

Cause

This is by design and was implemented after reports of issues with applications when the Hyper-V Time Synchronization Service adjusted the time.

If the system clock in the VM is ahead of the host for no more than five seconds, the Hyper-V Time Synchronization Service will adjust the system clock in the virtual machine. However, if the system clock in the VM is ahead for more than five seconds, the Hyper-V Time Synchronization Service will NOT adjust the system clock and there's no way to achieve time adjustment by changing integration service setting.

Workaround

There's no flag/property/setting that you can set to work around the timesync logic. However, below are a few workarounds that you may try to sync the time:

  1. Pause and resume the virtual machine.
  2. Power off and power on the virtual machine.
  3. Disable and enable the Time Synchronization option in the virtual machine settings (via the Hyper-V Manager console).
  4. Disable the Hyper-V Time Synchronization option, then use another time sync source and configure the PhaseCorrectRate, MaxPollInterval, MinPollInterval, and UpdateInterval values appropriately to get the Time Sync more closely. MaxpollInterval and MinPollInterval are the minimum and maximum interval between the polls respectively. The value in each is a time in log2 seconds (that is, 2^n, so if you specify 5 then the actual time would be 2^5 = 32 seconds). The default value for domain controllers for each of them respectively is 6 (64 seconds) and 10 (1,024 seconds).

See the below article to know more about Time Sync settings and how to configure them appropriately:

Windows Time Service Tools and Settings

Source: Microsoft Learn / IT Pro troubleshooting by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.

资料来源与适用范围

资料来源
Microsoft Learn / IT Pro troubleshooting
适用范围
- Supported versions of Windows Server · Source date 02/12/2026
内容语言
中文;命令、路径和错误标识保留技术原文
本地收录日期
2026-11-15
授权说明
CC BY 4.0 (documentation), MIT (code samples)

正文与所需资源由本站本地存储。查看来源及更新记录 ↗

请按适用版本和实际日志确认原因;本站没有对每一种系统或设备逐项执行文中的操作。