The Win32_LoadOrderGroup WMI class represents a group of system services that define execution dependencies. The services must be initiated in the order specified by the Load Order Group, as the services are dependent on each other. These dependent services require the presence of the antecedent services to function correctly. The data in this class is derived by the provider from the registry key: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\ServiceGroupOrder.
The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties. Properties are listed in alphabetic order, not MOF order.
Syntax
[Dynamic, Provider("CIMWin32"), UUID("{8502C4D4-5FBB-11D2-AAC1-006008C78BC7}"), AMENDMENT]
class Win32_LoadOrderGroup : CIM_LogicalElement
{
string Caption;
string Description;
datetime InstallDate;
string Status;
boolean DriverEnabled;
uint32 GroupOrder;
string Name;
};
Members
The Win32_LoadOrderGroup class has these types of members:
Properties
The Win32_LoadOrderGroup class has these properties.
Caption
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64), DisplayName ("Caption")
A short textual description of the object.
This property is inherited from CIM_ManagedSystemElement.
Description
Data type: string
Access type: Read-only
Qualifiers: DisplayName ("Description")
A textual description of the object.
This property is inherited from CIM_ManagedSystemElement.
DriverEnabled
Data type: boolean
Access type: Read-only
Qualifiers: MappingStrings ("Win32Registry|System\\CurrentControlSet\\Control\\GroupOrderList")
Indicates whether this load order group can include drivers along with system services.
GroupOrder
Data type: uint32
Access type: Read-only
Qualifiers: MappingStrings ("Win32Registry|System\\CurrentControlSet\\Control\\GroupOrderList")
Sequence in which this group of services is loaded onto the operating system.
Example: 2
InstallDate
Data type: datetime
Access type: Read-only
Qualifiers: MappingStrings ("MIF.DMTF|ComponentID|001.5"), DisplayName ("Install Date")
Indicates when the object was installed. Lack of a value does not indicate that the object is not installed.
This property is inherited from CIM_ManagedSystemElement.
Name
Data type: string
Access type: Read-only
Qualifiers: key, Override ("Name"), MappingStrings ("Win32Registry|System\\CurrentControlSet\\Control\\GroupOrderList")
Name of the load order group.
Example: "Primary disk"
Status
Data type: string
Access type: Read-only
Qualifiers: MaxLen (10), DisplayName ("Status")
String that indicates the current status of the object. Operational and non-operational status can be defined. Operational status can include "OK", "Degraded", and "Pred Fail". "Pred Fail" indicates that an element is functioning properly, but is predicting a failure (for example, a SMART-enabled hard disk drive).
Non-operational status can include "Error", "Starting", "Stopping", and "Service". "Service" can apply during disk mirror-resilvering, reloading a user permissions list, or other administrative work. Not all such work is online, but the managed element is neither "OK" nor in one of the other states.
This property is inherited from CIM_ManagedSystemElement.
Values include the following:
OK ("OK")
Error ("Error")
Degraded ("Degraded")
Unknown ("Unknown")
Pred Fail ("Pred Fail")
Starting ("Starting")
Stopping ("Stopping")
Service ("Service")
Stressed ("Stressed")
NonRecover ("NonRecover")
No Contact ("No Contact")
Lost Comm ("Lost Comm")
Remarks
The Win32_LoadOrderGroup class is derived from CIM_LogicalElement.
Requirements
| Requirement | Value |
|---|---|
| Minimum supported client | Windows Vista |
| Minimum supported server | Windows Server 2008 |
| Namespace | Root\CIMV2 |
| MOF | CIMWin32.mof |
| DLL | CIMWin32.dll |
See also