The JetCreateInstance function allocates a new instance of the database engine for use in a single process.

Windows XP:  JetCreateInstance is introduced in Windows XP.

    JET_ERR JET_API JetCreateInstance(
      __out         JET_INSTANCE* pinstance,
      __in_opt      const tchar* szInstanceName
    );

Parameters

pinstance

The output buffer that receives the newly-created instance.

szInstanceName

A unique string identifier for the instance to be created. This string must be unique within a given process hosting the database engine.

Note A NULL value is treated as a valid string identifier for an instance. Only one instance may have a NULL string identifier.

Return Value

This function returns the JET_ERR datatype with one of the following return codes. For more information about the possible ESE errors, see Extensible Storage Engine Errors and Error Handling Parameters.

Return code Description
JET_errSuccess The operation completed successfully.
JET_errInstanceNameInUse The specified instance name is already in use for this process.
JET_errInvalidParameter One of the parameters provided contained an unexpected value or contained a value that did not make sense when combined with the value of another parameter. This can happen for JetCreateInstance when pinstance is NULL.
JET_errRunningInOneInstanceMode The operation failed because it cannot be used when the database engine is operating in single instance mode (Windows 2000 compatibility mode).
JET_errTooManyInstances A new instance could not be created because the maximum number of instances has been reached. The maximum number of supported instances is configured using <a href="gg294044(v=exchg.10).md">JetSetSystemParameter</a> using JET_paramMaxInstances.

On success, a new instance will be allocated and the identifier for it will be returned. At this point, all system parameters for the instance will have the values of the global default system parameters. Once an instance will be allocated, it needs to be terminated and/or freed later on.

On failure, an error representing the cause of failure will be returned and no instance will be allocated.

Remarks

An instance must be initialized with a call to JetInit before it can be used by anything other than JetSetSystemParameter.

An instance is destroyed by a call to the JetTerm function, even if that instance was never initialized using JetInit. The maximum number of instances that may be created at any one time is controlled by JET_paramMaxInstances, which can be configured by a call to JetSetSystemParameter. An instance is the unit of recoverability for the database engine. It controls the life cycle of all the files used to protect the integrity of the data in a set of database files. These files include the checkpoint file and the transaction log files.

If the function succeeds, the database engine will automatically be changed to multi-instance mode as a side effect of this call. If the application desires to allow only one instance in the process then JetInit should be used to start the database engine in Windows 2000 compatibility mode.

If present, the szDisplayName will be used to identify the instance in places like Event Log or towards other callers like backup applications (through functions like JetGetInstanceInfo or JetOSSnapshotFreeze). If the display name is not provided, the unique szInstanceName will be used instead if present, otherwise an empty string will be returned. If the engine did not have the running mode set, after this call, it will be set to multi-instance mode.

The typical start-up sequence for a process potentially running multiple Jet instances would be:

If this is the first instance to be started, there are a number of additional steps which will be executed during this call in order to make basic system initialization and configuration. A number of those steps might result in specific errors starting with JET_errOutOfMemory but others as well (see errors above).

Requirements
Requirement Value
Client Requires Windows Vista or Windows XP.
Server Requires Windows Server 2008 or Windows Server 2003.
Header Declared in Esent.h.
Library Use ESENT.lib.
DLL Requires ESENT.dll.
Unicode Implemented as JetCreateInstanceW (Unicode) and JetCreateInstanceA (ANSI).
See Also

Extensible Storage Engine Files
JET_ERR
JET_INSTANCE
JetCreateInstance2
JetEnableMultiInstance
JetGetInstanceInfo
JetInit
JetInit2
JetOSSnapshotFreeze
JetSetSystemParameter
JetTerm
JetTerm2

Source: Microsoft Learn / Windows Win32 documentation by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.

资料来源与适用范围

资料来源
Microsoft Learn / Windows Win32 documentation
适用范围
Windows Win32 API · Source date 04/11/2016
内容语言
中文;命令、路径和错误标识保留技术原文
本地收录日期
2026-11-15
授权说明
CC BY 4.0 (documentation), MIT (code samples)

正文与所需资源由本站本地存储。查看来源及更新记录 ↗

请按适用版本和实际日志确认原因;本站没有对每一种系统或设备逐项执行文中的操作。