大网数据广告活动
网络与域名解析

WFP Error Codes (Winerror.h)

· 52CE 我爱测

Windows Filtering Platform (WFP) specific error codes are as follows.

Windows Filtering Platform (WFP) specific error codes are as follows.

FWP_E_CALLOUT_NOT_FOUND

0x80320001

The callout does not exist.

FWP_E_CONDITION_NOT_FOUND

0x80320002

The filter condition does not exist.

FWP_E_FILTER_NOT_FOUND

0x80320003

The filter does not exist.

FWP_E_LAYER_NOT_FOUND

0x80320004

The layer does not exist.

FWP_E_PROVIDER_NOT_FOUND

0x80320005

The provider does not exist.

FWP_E_PROVIDER_CONTEXT_NOT_FOUND

0x80320006

The provider context does not exist.

FWP_E_SUBLAYER_NOT_FOUND

0x80320007

The sub-layer does not exist.

FWP_E_NOT_FOUND

0x80320008

The object does not exist.

The IPsecSaContext* functions return this error if the SA context ID is not found.

FWP_E_ALREADY_EXISTS

0x80320009

An object with that GUID or LUID already exists.

FWP_E_IN_USE

0x8032000A

The object is referenced by other objects, so it cannot be deleted.

FWP_E_DYNAMIC_SESSION_IN_PROGRESS

0x8032000B

The call is not allowed from within a dynamic session.

FWP_E_WRONG_SESSION

0x8032000C

The call was made from the wrong session, so it cannot be completed.

FWP_E_NO_TXN_IN_PROGRESS

0x8032000D

The call must be made from within an explicit transaction.

FWP_E_TXN_IN_PROGRESS

0x8032000E

The call is not allowed from within an explicit transaction.

FWP_E_TXN_ABORTED

0x8032000F

The explicit transaction has been forcibly canceled.

FWP_E_SESSION_ABORTED

0x80320010

The session has been canceled.

The session handle needs to be closed by calling FwpmEngineClose0, even though it is no longer valid; otherwise, the client-side state will be leaked. A new session should be created by calling FwpmEngineOpen0.

FWP_E_INCOMPATIBLE_TXN

0x80320011

The call is not allowed from within a read-only transaction.

FWP_E_TIMEOUT

0x80320012

The call timed out while waiting to acquire the transaction lock.

FWP_E_NET_EVENTS_DISABLED

0x80320013

The collection of network diagnostic events is disabled.

FWP_E_INCOMPATIBLE_LAYER

0x80320014

The operation is not supported by the specified layer.

FWP_E_KM_CLIENTS_ONLY

0x80320015

The call is allowed for kernel-mode callers only.

FWP_E_LIFETIME_MISMATCH

0x80320016

The call tried to associate two objects with incompatible lifetimes.

See Object Management for more information on object lifetime and object association.

FWP_E_BUILTIN_OBJECT

0x80320017

The object is built-in, so it cannot be deleted.

FWP_E_TOO_MANY_CALLOUTS

0x80320018

The maximum number of callouts has been reached.

At most, 100,000 callouts can be registered at the same time.

FWP_E_NOTIFICATION_DROPPED

0x80320019

A notification could not be delivered because a message queue is at its maximum capacity.

FWP_E_TRAFFIC_MISMATCH

0x8032001A

The network traffic parameters do not match those for the security association context.

IPsecSaContextGetSpi0 can be called multiple times, but the caller must specify the same IPSEC_TRAFFIC0 each time. This error is returned if a subsequent call supplies a different IPSEC_TRAFFIC0.

FWP_E_INCOMPATIBLE_SA_STATE

0x8032001B

The call is not allowed for the current security association (SA) state.

The SA context functions must be called in a specific order:

This error is returned if they are called out of order.

FWP_E_NULL_POINTER

0x8032001C

A required pointer is null.

FWP_E_INVALID_ENUMERATOR

0x8032001D

An enumerator value in a structure is out of range.

FWP_E_INVALID_FLAGS

0x8032001E

The flags field contains an invalid value.

FWP_E_INVALID_NET_MASK

0x8032001F

A network mask is not valid.

FWP_E_INVALID_RANGE

0x80320020

An FWP_RANGE0 structure is not valid.

FWP_E_INVALID_INTERVAL

0x80320021

The time interval is not valid.

FWP_E_ZERO_LENGTH_ARRAY

0x80320022

An array that must contain at least one element has zero length.

FWP_E_NULL_DISPLAY_NAME

0x80320023

The displayData.name field cannot be null.

FWP_E_INVALID_ACTION_TYPE

0x80320024

The action type is not one of the allowed action types for a filter.

FWP_E_INVALID_WEIGHT

0x80320025

The filter weight is not valid.

See Filter Weight Assignment for more information.

FWP_E_MATCH_TYPE_MISMATCH

0x80320026

A filter condition contains a match type that is not compatible with the operands.

See FWP_MATCH_TYPE for more information.

FWP_E_TYPE_MISMATCH

0x80320027

An FWP_VALUE0 structure or an FWPM_CONDITION_VALUE0 structure is of the wrong type.

FWP_E_OUT_OF_BOUNDS

0x80320028

An integer value is outside the allowed range.

FWP_E_RESERVED

0x80320029

A reserved field is nonzero.

FWP_E_DUPLICATE_CONDITION

0x8032002A

A filter cannot contain multiple conditions operating on a single field.

FWP_E_DUPLICATE_KEYMOD

0x8032002B

A policy cannot contain the same keying module more than once.

FWP_E_ACTION_INCOMPATIBLE_WITH_LAYER

0x8032002C

The action type is not compatible with the layer.

FWP_E_ACTION_INCOMPATIBLE_WITH_SUBLAYER

0x8032002D

The action type is not compatible with the sub-layer.

FWP_E_CONTEXT_INCOMPATIBLE_WITH_LAYER

0x8032002E

The raw context or the provider context is not compatible with the layer.

FWP_E_CONTEXT_INCOMPATIBLE_WITH_CALLOUT

0x8032002F

The raw context or the provider context is not compatible with the callout.

FWP_E_INCOMPATIBLE_AUTH_METHOD

0x80320030

The authentication method is not compatible with the policy type.

FWP_E_INCOMPATIBLE_DH_GROUP

0x80320031L

The Diffie-Hellman group is not compatible with the policy type.

FWP_E_EM_NOT_SUPPORTED

0x80320032

An IKE policy cannot contain an Extended Mode policy.

FWP_E_NEVER_MATCH

0x80320033

The enumeration template or subscription will never match any objects.

FWP_E_PROVIDER_CONTEXT_MISMATCH

0x80320034

The provider context is of the wrong type.

FWP_E_INVALID_PARAMETER

0x80320035

The parameter is incorrect.

Possible reasons for this error:

  • FwpmIPsecTunnelAdd0 was called without setting the flag FWPM_TUNNEL_FLAG_POINT_TO_POINT and with conditions other than local/remote address.
  • An invalid Unicode string, or a Unicode string that contains unprintable characters.

FWP_E_TOO_MANY_SUBLAYERS

0x80320036

The maximum number of sublayers has been reached.

WFP supports at most 2 6 sublayers.

FWP_E_CALLOUT_NOTIFICATION_FAILED

0x80320037

The notification function for a callout returned an error.

FWP_E_INVALID_AUTH_TRANSFORM

0x80320038

The IPsec authentication transform is not valid.

FWP_E_INVALID_CIPHER_TRANSFORM

0x80320039

The IPsec cipher transform is not valid.

Requirements

Requirement Value
Minimum supported client Windows Vista [desktop apps only]
Minimum supported server Windows Server 2008 [desktop apps only]
Header Winerror.h

Source: Microsoft Learn / Windows Win32 documentation by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.

资料来源与适用范围

资料来源
Microsoft Learn / Windows Win32 documentation
适用范围
Windows Win32 API · Source date 05/31/2018
内容语言
中文;命令、路径和错误标识保留技术原文
本地收录日期
2026-11-15
授权说明
CC BY 4.0 (documentation), MIT (code samples)

正文与所需资源由本站本地存储。查看来源及更新记录 ↗

请按适用版本和实际日志确认原因;本站没有对每一种系统或设备逐项执行文中的操作。