Represents the transport connection for the Microsoft TCP/IP WMI v2 provider.
The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.
Syntax
[UMLPackagePath("CIM::Network::Pipes"), ClassVersion("1.0.0"), dynamic, provider("nettcpip"), AMENDMENT]
class MSFT_NetTransportConnection : CIM_NetworkPipe
{
string Caption;
string Description;
string ElementName;
datetime InstallDate;
string Name;
uint16 OperationalStatus[];
string StatusDescriptions[];
string Status;
uint16 HealthState;
uint16 CommunicationStatus;
uint16 DetailedStatus;
uint16 OperatingStatus;
uint16 PrimaryStatus;
string OtherEnabledState;
uint16 EnabledDefault = 2;
datetime TimeOfLastStateChange;
uint16 TransitioningToState = 12;
uint16 AvailableRequestedStates[];
string InstanceID;
uint16 EnabledState;
uint16 RequestedState = 5;
uint16 Directionality;
uint16 AggregationBehavior;
string LocalAddress;
uint16 LocalPort;
};
Members
The MSFT_NetTransportConnection class has these types of members:
Methods
The MSFT_NetTransportConnection class has these methods.
| Method | Description |
|---|---|
| RequestStateChange | Requests that the state of the element be changed to the value specified in the RequestedState parameter. When the requested state change takes place, the enabled state and requested state of the element will be the same. Invoking the RequestChangeState method multiple times could result in earlier requests being overwritten or lost. If 0 is returned, then the task completed successfully and the use of CIM_ConcreteJob was not required. If 4096 (0x1000) is returned, then the task will take some time to complete, CIM_ConcreteJob will be created, and its reference returned in the output parameter Job. Any other return code indicates an error condition. This method is inherited from CIM_EnabledLogicalElement. |
Properties
The MSFT_NetTransportConnection class has these properties.
AggregationBehavior
Data type: uint16
Access type: Read-only
Indicates whether the pipe is composed of lower-level pipes, and if so, how these lower-level pipes are aggregated (in parallel or in sequence). The specific instances of NetworkPipe that are combined are described using the NetworkPipeComposition association.
This property is inherited from CIM_NetworkPipe.
Unknown (0)
No Lower-Level Composition (2)
Combined In Parallel (3)
Combined In Sequence (4)
AvailableRequestedStates
Data type: uint16 array
Access type: Read-only
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.RequestStateChange", "CIM_EnabledLogicalElementCapabilities.RequestedStatesSupported")
AvailableRequestedStates indicates the possible values for the RequestedState parameter of the method RequestStateChange, used to initiate a state change. The values listed shall be a subset of the values contained in the RequestedStatesSupported property of the associated instance of CIM_EnabledLogicalElementCapabilities where the values selected are a function of the current state of the CIM_EnabledLogicalElement. This property may be non-null if an implementation is able to advertise the set of possible values as a function of the current state. This property shall be null if an implementation is unable to determine the set of possible values as a function of the current state.
This property is inherited from CIM_EnabledLogicalElement.
Enabled (2)
Disabled (3)
Shut Down (4)
Offline (6)
Test (7)
Defer (8)
Quiesce (9)
Reboot (10)
Reset (11)
DMTF Reserved (12 65535)
Caption
Data type: string
Access type: Read-only
Qualifiers: MaxLen (64)
Contains a short textual description of the object.
This property is inherited from CIM_ManagedElement.
CommunicationStatus
Data type: uint16
Access type: Read-only
Indicates the ability of the instrumentation to communicate with this element. A NULL value indicates that instrumentation does not support this property.
This property is inherited from CIM_ManagedSystemElement.
| Values | Meaning |
|---|---|
| Unknown 0 | Indicates that the instrumentation cannot report on the CommunicationStatus property at this time. |
| Not Available 1 | Indicates that the instrumentation is capable of reporting this property, but intentionally does not for this element. |
| Communication OK 2 | Indicates only that communication is established with the element. |
| Lost Communication 3 | Indicates that the element has been contacted in the past, but is currently unreachable. |
| No Contact 4 | Indicates that the instrumentation has contact information for this element, but has never been able to communicate with it. |
| DMTF Reserved 5 32767 | Reserved. |
| Vendor Reserved 32768 = value | Reserved. |
Description
Data type: string
Access type: Read-only
Provides a textual description of the object.
This property is inherited from CIM_ManagedElement.
DetailedStatus
Data type: uint16
Access type: Read-only
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.PrimaryStatus", "CIM_ManagedSystemElement.HealthState")
Indicates additional status details that complement the PrimaryStatus property. A NULL value indicates that the instrumentation does not support this property.
This property is inherited from CIM_ManagedSystemElement.
| Values | Meaning |
|---|---|
| Not Available 0 | Indicates that the instrumentation is capable of reporting this property, but intentionally does not report it for this element. |
| No Additional Information 1 | Indicates that no details have to be added to the PrimaryStatus property, for example when the PrimaryStatus is set to OK. |
| Stressed 2 | Indicates that the element functions, but requires attention. Overload and overheated are examples of Stressed states. |
| Predictive Failure 3 | Indicates that an element functions nominally, but predicts a failure in the near future. |
| Non-Recoverable Error 4 | Indicates that this element is in an error condition that requires human intervention. |
| Supporting Entity in Error 5 | Indicates that an element on which this element depends is in error. This element might be OK but cannot function because of the state of a dependent element. An example is a network service or endpoint that cannot function due to lower-layer networking problems. |
| DMTF Reserved 6 32767 | Reserved. |
| Vendor Reserved 32768 = value | Reserved. |
Directionality
Data type: uint16
Access type: Read-only
Indicates the directionality of the pipe. For unidirectional pipes, the source and sink are indicated by a property (SourceOrSink) of the association, EndpointOfNetworkPipe.
This property is inherited from CIM_NetworkPipe.
Unknown (0)
Bi-Directional (2)
Unidirectional (3)
ElementName
Data type: string
Access type: Read-only
Contains a user-friendly name for the object. This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information.
This property is inherited from CIM_ManagedElement.
EnabledDefault
Data type: uint16
Access type: Read/write
An enumerated value indicating an administrator's default or startup configuration for the Enabled State of an element. By default, the element is "Enabled" (value=2).
This property is inherited from CIM_EnabledLogicalElement.
Enabled (2)
Disabled (3)
Not Applicable (5)
Enabled but Offline (6)
No Default (7)
Quiesce (9)
DMTF Reserved (10 32767)
Vendor Reserved (32768 65535)
EnabledState
Data type: uint16
Access type: Read-only
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.OtherEnabledState")
EnabledState is an integer enumeration that indicates the enabled and disabled states of an element. It can also indicate the transitions between these requested states. For example, shutting down (value=4) and starting (value=10) are transient states between enabled and disabled.
This property is inherited from CIM_NetworkPipe.
| Value | Meaning |
|---|---|
| Unknown 0 | The element state is unknown. |
| Other 1 | The element is in a state other than one listed here. |
| Enabled 2 | The element is or could be executing commands, will process any queued commands, and queues new requests. |
| Disabled 3 | The element will not execute commands and will drop any new requests. |
| Shutting Down 4 | The element is in the process of going to a Disabled state. |
| Not Applicable 5 | The element does not support being enabled or disabled. |
| Enabled but Offline 6 | The element might be completing commands, and will drop any new requests. |
| In Test 7 | The element is in a test state. |
| Deferred 8 | The element might be completing commands, but will queue any new requests. |
| Quiesce 9 | The element is enabled but in a restricted mode. |
| Starting 10 | The element is in the process of going to an Enabled state. New requests are queued. |
| DMTF Reserved 11 32767 | |
| Vendor Reserved 32768 65535 |
HealthState
Data type: uint16
Access type: Read-only
Indicates the current health of the element. This attribute expresses the health of this element but not necessarily that of its sub-components.
This property is inherited from CIM_ManagedSystemElement.
| Values | Meaning |
|---|---|
| Unknown 0 | The implementation cannot report on HealthState at this time. |
| OK 5 | The element is fully functional and is operating within normal operational parameters and without error. |
| Degraded/Warning 10 | The element is in working order and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors |
| Minor failure 15 | All functionality is available but some might be degraded. |
| Major failure 20 | The element is failing. It is possible that some or all of the functionality of this component is degraded or not working. |
| Critical failure 25 | The element is non-functional and recovery might not be possible. |
| Non-recoverable error 30 | The element has completely failed, and recovery is not possible. All functionality provided by this element has been lost. |
| DMTF Reserved 31 = value | DMTF has reserved the unused portion of the continuum for additional HealthStates values in the future. |
InstallDate
Data type: datetime
Access type: Read-only
Indicates when the object was installed. The lack of a value does not indicate that the object is not installed.
This property is inherited from CIM_ManagedSystemElement.
InstanceID
Data type: string
Access type: Read-only
Qualifiers: key
Uniquely and opaquely identifies an instance of this class within the scope of the containing Namespace.
[!Important]In order to ensure uniqueness within the Namespace, the value of InstanceID should be constructed in the following pattern:
OrgID:LocalID
OrgID must include a copyrighted, trademarked or otherwise unique name that is owned by the business entity defining the InstanceID, or be a registered ID that is assigned by a recognized global authority. This is similar to the structure of Schema class names. In addition, to ensure uniqueness the first colon in InstanceID must be between the OrgID andLocalID. Therefore the OrgID must not contain a colon (':').
LocalID is chosen by the business entity and should not be re-used to identify different underlying real-world elements.
If the preceding pattern is not used, the defining entity must assure that the resultant InstanceID is not re-used across any InstanceIDs produced by this or other providers for this Namespace.
For Distributed Management Task Force (DMTF) defined instances, the pattern must be used with the OrgID set to CIM.
This property is inherited from CIM_NetworkPipe.
LocalAddress
Data type: string
Access type: Read-only
The local address of the transport connection.
LocalPort
Data type: uint16
Access type: Read-only
The local port of the transport connection.
Name
Data type: string
Access type: Read-only
Qualifiers: MaxLen (1024)
Indicates the user-friendly name for this instance of a job. In addition, the user-friendly name can be used as a property for a search or query.
[!Tip]
Name does not have to be unique within a namespace.
This property is inherited from CIM_ManagedSystemElement.
OperatingStatus
Data type: uint16
Access type: Read-only
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
Indicates the current operational condition of the element. This property can be used to provide more detail about the current state of the element. It can also indicate transitional states. A NULL value indicates that the instrumentation does not support this property.
This property is inherited from CIM_ManagedSystemElement.
| Value | Meaning |
|---|---|
| Unknown 0 | Indicates that the instrumentation cannot report on the OperatingStatus property at this time. |
| Not Available 1 | Indicates that the instrumentation is capable of reporting this property, but intentionally does not report it for this element. |
| Servicing 2 | Indicates that the element is in process to be configured, maintained, cleaned, or otherwise administered. |
| Starting 3 | Indicates that the element is being initialized. |
| Stopping 4 | Indicates that the element is being brought to an orderly stop. |
| Stopped 5 | Indicates that the element is intentionally stopped. |
| Aborted 6 | Indicates that the element stopped in an unexpected way. |
| Dormant 7 | Indicates that the element is inactive or quiesced. |
| Completed 8 | Indicates that the element completed its operation. We recommend using a PrimaryStatus property value of OK, Error, or Degraded to indicate success or failure of the operation. |
| Migrating 9 | Indicates that the element is being moved between host elements. |
| Emigrating 10 | Indicates that the element is being moved away from the host element. |
| Immigrating 11 | Indicates that the element is being moved to a new host element. |
| Snapshotting 12 | Indicates that a snapshot copy of the element is being created. |
| Shutting Down 13 | Indicates that the element is being brought to an abrupt stop. |
| In Test 14 | Indicates that the element is performing test functions. |
| Transitioning 15 | Indicates that the element is between states and is not fully available in either state. Use another value that indicates a more specific transition if one is available. |
| In Service 16 | Indicates that the element is in service and operational. |
| DMTF Reserved 17 32767 | Reserved. |
| Vendor Reserved 32768 = value | Reserved. |
OperationalStatus
Data type: uint16 array
Access type: Read-only
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.StatusDescriptions")
Contains indicators of the current status of the element. The first value of OperationalStatus should contain the primary status for the element.
Note:
OperationalStatus replaces the deprecated Status property. Due to the widespread use of the existing Status property in management applications, Microsoft strongly recommends that providers or instrumentation provide both the Status and OperationalStatus properties. When instrumented, Status (because it is single-valued) should also provide the primary status of the element.
This property is inherited from CIM_ManagedSystemElement.
| Values | Meaning |
|---|---|
| Unknown 0 | Indicates the implementation cannot report on OperationalStatus at this time. |
| Other 1 | Indicates an undefined state. |
| OK 2 | Indicates full functionality without errors. |
| Degraded 3 | Indicates the element is working and all functionality is provided. However, the element is not working to the best of its abilities. For example, the element might not be operating at optimal performance or it might be reporting recoverable errors |
| Stressed 4 | Indicates that the element is functioning, but needs attention. Overload and overheated are examples of Stressed states. |
| Predictive Failure 5 | Indicates that an element is functioning nominally but predicting a failure in the near future. |
| Error 6 | Indicates that an error has occurred. |
| Non-Recoverable Error 7 | A nonrecoverable error has occurred. |
| Starting 8 | The job is starting. |
| Stopping 9 | The job is stopping. |
| Stopped 10 | The element has been intentionally stopped. |
| In Service 11 | Indicates the element is being configured, maintained, cleaned, or otherwise administered. |
| No Contact 12 | Indicates that the monitoring system has knowledge of this element, but has never been able to establish communications with it. |
| Lost Communication 13 | Indicates that the job is known to exist and has been contacted successfully in the past, but is currently unreachable. |
| Aborted 14 | Indicates the job stopped in an unexpected way. The state and configuration of the job might need to be updated. |
| Dormant 15 | Indicates that the job is inactive. |
| Supporting Entity in Error 16 | Indicates that an element on which this job depends is in error. This element may be OK but is unable to function because of the state of a dependent element. An example is a network service or endpoint that cannot function due to lower-layer networking problems. |
| Completed 17 | Indicates that the job has completed its operation. This value should be combined with either OK, ErrorError, or Degraded so that a client can tell if the complete operation Completed with OK (passed), Completed with Error (failed), or Completed with Degraded (the operation finished, but it did not complete OK or did not report an error). |
| Power Mode 18 | "Power Mode" indicates that the element has additional power model information contained in the associated PowerManagementService association. |
| DMTF Reserved 19 32767 | DMTF has reserved this portion of the range for additional OperationalStatus values in the future. |
| Vendor Reserved 32768 65535 | Microsoft has reserved the unused portion of the range for additional OperationalStatus values in the future. |
OtherEnabledState
Data type: string
Access type: Read-only
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
A string that describes the enabled or disabled state of the element when the EnabledState property is set to 1 ("Other"). This property must be set to null when EnabledState is any value other than 1.
This property is inherited from CIM_EnabledLogicalElement.
PrimaryStatus
Data type: uint16
Access type: Read-only
Qualifiers: ModelCorrespondence ("CIM_ManagedSystemElement.DetailedStatus", "CIM_ManagedSystemElement.HealthState")
Indicates a high-level status value.
This property is inherited from CIM_ManagedSystemElement.
The possible values are.
Unknown (0)
OK (1)
Degraded (2)
Error (3)
DMTF Reserved (4 32767)
Vendor Reserved (32768 = value )
RequestedState
Data type: uint16
Access type: Read/write
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")
RequestedState is an integer enumeration that indicates the last requested or desired state for the element, irrespective of the mechanism through which it was requested. The actual state of the element is represented by EnabledState. This property is provided to compare the last requested and current enabled or disabled states. Note that when EnabledState is set to 5 ("Not Applicable"), then this property has no meaning. Refer to the EnabledState property description for explanations of the values in the RequestedState enumeration.
This property is inherited from CIM_NetworkPipe.
| Value | Meaning |
|---|---|
| Unknown 0 | the last requested state for the element is unknown. |
| Enabled 2 | |
| Disabled 3 | requests an immediate disabling of the element, such that it will not execute or accept any commands or processing requests. |
| Shut Down 4 | Requests an orderly transition to the Disabled state, and might involve removing power, to completely erase any existing state. |
| No Change 5 | Deprecated in lieu of indicating the last requested state is "Unknown" (0). If the last requested or desired state is unknown, RequestedState should have the value "Unknown" (0), but may have the value "No Change" (5). |
| Offline 6 | The element has been requested to transition to the Enabled but Offline EnabledState. |
| Test 7 | |
| Deferred 8 | |
| Quiesce 9 | |
| Reboot 10 | Refers to doing a "Shut Down" and then moving to an "Enabled" state. |
| Reset 11 | Reset indicates that the element is first "Disabled" and then "Enabled". |
| Not Applicable 12 | Knowledge of the last RequestedState is not supported for the EnabledLogicalElement. |
| DMTF Reserved 13 32767 | |
| Vendor Reserved 32768 65535 |
Status
Data type: string
Access type: Read-only
Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus"), MaxLen (10)
Contains a string indicating the primary status of the object.
Note:
This property is deprecated and replaced by the OperationalStatus property. If you choose to use the Status property for backward compatibility it should be secondary to the OperationalStatus property.
This property is inherited from CIM_ManagedSystemElement.
The possible values are.
("OK")
("Error")
("Degraded")
("Unknown")
("Pred Fail")
("Starting")
("Stopping")
("Service")
("Stressed")
("NonRecover")
("No Contact")
("Lost Comm")
("Stopped")
StatusDescriptions
Data type: string array
Access type: Read-only
Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.OperationalStatus")
Indicates descriptions of the corresponding values in the OperationalStatus array. For example, if an element in the OperationalStatus property contains the value Stopping, then the element at the same array index in this property might contain an explanation as to why an object is being stopped.
This property is inherited from CIM_ManagedSystemElement.
TimeOfLastStateChange
Data type: datetime
Access type: Read-only
The date or time when the enabled state of the element last changed. If the state of the element has not changed and this property is populated, then it must be set to a 0 interval value. If a state change was requested, but rejected or not yet processed, the property must not be updated.
This property is inherited from CIM_EnabledLogicalElement.
TransitioningToState
Data type: uint16
Access type: Read-only
Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.RequestStateChange", "CIM_EnabledLogicalElement.RequestedState", "CIM_EnabledLogicalElement.EnabledState")
TransitioningToState indicates the target state to which the instance is transitioning.
A value of 5 "No Change" shall indicate that no transition is in progress.A value of 12 "Not Applicable" shall indicate the implementation does not support representing ongoing transitions.
A value other than 5 or 12 shall identify the state to which the element is in the process of transitioning.
This property is inherited from CIM_EnabledLogicalElement.
Unknown (0)
Enabled (2)
Disabled (3)
Shut Down (4)
No Change (5)
Offline (6)
Test (7)
Defer (8)
Quiesce (9)
Reboot (10)
Reset (11)
Not Applicable (12)
DMTF Reserved (13 65535)
Requirements
| Requirement | Value |
|---|---|
| Minimum supported client | Windows 8 |
| Minimum supported server | Windows Server 2012 |
| Namespace | Root\StandardCimv2 |
| MOF | NetTCPIP.mof |
| DLL | NetTCPIP.dll |
Source: Microsoft Learn / Windows Win32 documentation by Microsoft and contributors (upstream author metadata: windowssdkdev). Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.