Filters traffic based on certain high-level security constraints, like whether or not the traffic is encrypted. Connection Security rules will have to be created in order for traffic to pass the rule.

Filters traffic based on certain high-level security constraints, like whether or not the traffic is encrypted. Connection Security rules will have to be created in order for traffic to pass the rule.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.

Syntax

class MSFT_NetNetworkLayerSecurityFilter : CIM_FilterEntryBase
{
  uint16   Authentication;
  uint16   Encryption;
  boolean  OverrideBlockRules;
  string   LocalUsers;
  string   RemoteUsers;
  string   RemoteMachines;
  string   Name;
  string   SystemCreationClassName;
  string   SystemName;
  string   CreationClassName;
  boolean  IsNegated;
  datetime InstallDate;
  uint16   OperationalStatus[];
  string   StatusDescriptions[];
  string   Status;
  uint16   HealthState;
  uint16   CommunicationStatus;
  uint16   DetailedStatus;
  uint16   OperatingStatus;
  uint16   PrimaryStatus;
  string   InstanceID;
  string   Caption;
  string   Description;
  string   ElementName;
};

Members

The MSFT_NetNetworkLayerSecurityFilter class has these types of members:

Properties

The MSFT_NetNetworkLayerSecurityFilter class has these properties.

Authentication

Data type: uint16

Access type: Read-only

Whether to require Authentication. NoEncapsulation means that authentication is still required, but only once at the beginning of the traffic flow, instead of on every packet.

NotRequired (0)

Required (1)

NoEncapsulation (2 )

Caption

Data type: string

Access type: Read-only

Used in CimInstance.ToString(). A short string for describing this instance when debugging.

CommunicationStatus

Data type: uint16

Access type: Read-only

This field is ignored.

CreationClassName

Data type: string

Access type: Read-only

Reserved for internal use by the WMI provider only.

Description

Data type: string

Access type: Read-only

This field is ignored.

DetailedStatus

Data type: uint16

Access type: Read-only

This field is ignored.

ElementName

Data type: string

Access type: Read-only

This field is ignored.

Encryption

Data type: uint16

Access type: Read-only

Whether to require Encryption. Dynamic encryption means that the first packet may be protected but not encrypted.

NotRequired (0)

Required (1)

Dynamic (2 )

HealthState

Data type: uint16

Access type: Read-only

This field is ignored.

InstallDate

Data type: datetime

Access type: Read-only

This field is ignored.

InstanceID

Data type: string

Access type: Read-only

A string that uniquely identifies this instance within the PolicyStore.

IsNegated

Data type: boolean

Access type: Read-only

This field is ignored.

LocalUsers

Data type: string

Access type: Read-only

SDDL string describing Local Users that are allowed by this rule. If this is empty, all users are allowed. If LocalUsers/RemoteUsers/RemoteMachines are specified, then they apply conjunctively, and this is an 'Allow-Bypass' rule and ProtectionLevel must be set above None (so that authentication is required).

Name

Data type: string

Access type: Read-only

Reserved for internal use by the WMI provider only.

OperatingStatus

Data type: uint16

Access type: Read-only

This field is ignored.

OperationalStatus

Data type: uint16 array

Access type: Read-only

This field is ignored.

OverrideBlockRules

Data type: boolean

Access type: Read-only

Whether to allow this rule to take precedence over Block rules. This setting may only be applied on Allow rules that require Authentication with specific RemoteUsers and/or RemoteMachines.

PrimaryStatus

Data type: uint16

Access type: Read-only

This field is ignored.

RemoteMachines

Data type: string

Access type: Read-only

SDDL string describing Remote Machines that are allowed by this rule. If this is empty, all users are allowed. If LocalUsers/RemoteUsers/RemoteMachines are specified, then they apply conjunctively, and this is an 'Allow-Bypass' rule and ProtectionLevel must be set above None (so that authentication is required).

RemoteUsers

Data type: string

Access type: Read-only

SDDL string describing Remote Users that are allowed by this rule. If this is empty, all users are allowed. If LocalUsers/RemoteUsers/RemoteMachines are specified, then they apply conjunctively, and this is an 'Allow-Bypass' rule and ProtectionLevel must be set above None (so that authentication is required).

Status

Data type: string

Access type: Read-only

This field is ignored.

StatusDescriptions

Data type: string array

Access type: Read-only

This field is ignored.

SystemCreationClassName

Data type: string

Access type: Read-only

Reserved for internal use by the WMI provider only.

SystemName

Data type: string

Access type: Read-only

Reserved for internal use by the WMI provider only.

Requirements

Requirement Value
Minimum supported client Windows 8
Minimum supported server Windows Server 2012
Namespace Root\StandardCimv2
MOF WFasCim.mof
DLL WFasCim.dll

Source: Microsoft Learn / Windows Win32 documentation by Microsoft and contributors (upstream author metadata: windowssdkdev). Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.

资料来源与适用范围

资料来源
Microsoft Learn / Windows Win32 documentation
适用范围
Windows Win32 API · Source date 05/31/2018
内容语言
中文;命令、路径和错误标识保留技术原文
本地收录日期
2026-11-15
授权说明
CC BY 4.0 (documentation), MIT (code samples)