Indicates the state of an active remote session interacting with a virtual machine. There can only be one connection at a time.
The following syntax is simplified Managed Object Format (MOF) code, and it includes all of the inherited properties.
Syntax
[Dynamic, Provider("VmmsWmiInstanceAndMethodProvider"), AMENDMENT]
class Msvm_TerminalConnection : CIM_EnabledLogicalElement
{
string InstanceID;
string Caption;
string Description;
string ElementName;
datetime InstallDate;
string Name;
uint16 OperationalStatus[] = { 2 };
string StatusDescriptions[] = { "OK" };
string Status;
uint16 HealthState = 5;
uint16 CommunicationStatus;
uint16 DetailedStatus;
uint16 OperatingStatus;
uint16 PrimaryStatus;
uint16 EnabledState = 5;
string OtherEnabledState;
uint16 RequestedState = 12;
uint16 EnabledDefault = 2;
datetime TimeOfLastStateChange;
uint16 AvailableRequestedStates[];
uint16 TransitioningToState = 12;
string ConnectionID;
};
Members
The Msvm_TerminalConnection class has these types of members:
Methods
The Msvm_TerminalConnection class has these methods.
| Method | Description |
|---|---|
| RequestStateChange | Requests a state change. |
Properties
The Msvm_TerminalConnection class has these properties.
AvailableRequestedStates
Data type: uint16 array
Access type: Read-only
Indicates the possible values for the RequestedState parameter of the RequestStateChange method. This property is inherited from CIM_EnabledLogicalElement, and it is always set to Null.
Caption
Data type: string
Access type: Read-only
A short description of the object. This property is inherited from CIM_ManagedElement.
CommunicationStatus
Data type: uint16
Access type: Read-only
Indicates the ability of the instrumentation to communicate with the underlying managed element. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
Unknown (0)
Not Available (1)
Communication OK (2)
Lost Communication (3)
No Contact (4)
DMTF Reserved (..)
Vendor Reserved (0x8000.. )
ConnectionID
Data type: string
Access type: Read-only
Qualifiers: Key
The unique identifier for an instance of the terminal connection object. The identifier is of the form "Microsoft:VMID\Index". For example, "Microsoft:67A5D397-A02D-11DB-AC13-001676AA34F0\0".
Description
Data type: string
Access type: Read-only
A description of the object. This property is inherited from CIM_ManagedElement.
DetailedStatus
Data type: uint16
Access type: Read-only
Compliments the PrimaryStatus property with additional status detail. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
Not Available (0)
No Additional Information (1)
Stressed (2)
Predictive Failure (3)
Non-Recoverable Error (4)
Supporting Entity in Error (5)
DMTF Reserved (..)
Vendor Reserved (0x8000.. )
ElementName
Data type: string
Access type: Read-only
A display name for the object. This property is inherited from CIM_ManagedElement.
EnabledDefault
Data type: uint16
Access type: Read-only
An administrator's default or startup configuration for the enabled state of an element. This property is inherited from CIM_EnabledLogicalElement.
| Value | Meaning |
|---|---|
| 2 | Enabled |
| 3 | Disabled |
EnabledState
Data type: uint16
Access type: Read-only
The enabled and disabled states of an element. It can also indicate the transitions between these requested states. This property is inherited from CIM_EnabledLogicalElement.
| Value | Meaning |
|---|---|
| 2 | Enabled |
| 3 | Disabled |
| 5 | Not Applicable |
HealthState
Data type: uint16
Access type: Read-only
The current health of the element. This attribute expresses the health of this element but not necessarily that of its subcomponents. The possible values are 0 to 30, where 5 means the element is entirely healthy and 30 means the element is completely nonfunctional. This property is inherited from CIM_ManagedSystemElement, and it is always set to 5 (OK).
InstallDate
Data type: datetime
Access type: Read-only
The date and time the virtual machine configuration was created. This property is inherited from CIM_ManagedSystemElement.
InstanceID
Data type: string
Access type: Read-only
Qualifiers: Key
Uniquely identifies an instance of this class. This property is inherited from CIM_ManagedElement.
Name
Data type: string
Access type: Read-only
The label by which the object is known. This property is inherited from CIM_ManagedSystemElement, and it is the same as the ElementName property.
OperatingStatus
Data type: uint16
Access type: Read-only
Provides current status information for the operational condition of the element and can be used for providing more detail with respect to the value of the EnabledState property. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
Unknown (0)
Not Available (1)
Servicing (2)
Starting (3)
Stopping (4)
Stopped (5)
Aborted (6)
Dormant (7)
Completed (8)
Migrating (9)
Emigrating (10)
Immigrating (11)
Snapshotting (12)
Shutting Down (13)
In Test (14)
Transitioning (15)
In Service (16)
DMTF Reserved (..)
Vendor Reserved (0x8000.. )
OperationalStatus
Data type: uint16 array
Access type: Read-only
The current statuses of the object. This property is inherited from CIM_ManagedSystemElement.
OtherEnabledState
Data type: string
Access type: Read-only
A string that describes the enabled or disabled state of the element when the EnabledState property is set to 1 (Other). This property must be set to Null when EnabledState is any value other than 1. This property is inherited from CIM_EnabledLogicalElement, and it is always set to Null.
PrimaryStatus
Data type: uint16
Access type: Read-only
Provides high level status information. This property should be used in conjunction with the DetailedStatus property to provide high level and detailed health status of the element and its subcomponents. A Null value indicates that this property is not implemented. This property is inherited from CIM_ManagedSystemElement.
Unknown (0)
OK (1)
Degraded (2)
Error (3)
DMTF Reserved (..)
Vendor Reserved (0x8000.. )
RequestedState
Data type: uint16
Access type: Read-only
The last requested or desired state for the element. The actual state of the element is represented by EnabledState. This property is provided to compare the last requested and current enabled or disabled states. A particular instance of CIM_EnabledLogicalElement might not support RequestStateChange. If this occurs, the value 12 is used. This property is inherited from CIM_EnabledLogicalElement.
| Value | Meaning |
|---|---|
| 12 | Not Applicable |
Status
Data type: string
Access type: Read-only
The current status of the object. This property is inherited from CIM_ManagedSystemElement, but it is not used.
StatusDescriptions
Data type: string array
Access type: Read-only
Strings that describe the various OperationalStatus array values. This property is inherited from CIM_ManagedSystemElement.
TimeOfLastStateChange
Data type: datetime
Access type: Read-only
The date or time when the enabled state of the element last changed. This property is inherited from CIM_EnabledLogicalElement, and it is always set to Null.
TransitioningToState
Data type: uint16
Access type: Read-only
Indicates the target state to which the instance is transitioning. This property is inherited from CIM_EnabledLogicalElement.
| Value | Meaning |
|---|---|
| 12 | Not Applicable |
Remarks
Access to the Msvm_TerminalConnection class might be restricted by UAC Filtering. For more information, see User Account Control and WMI.
Requirements
| Requirement | Value |
|---|---|
| Minimum supported client | Windows 8 [desktop apps only] |
| Minimum supported server | Windows Server 2012 [desktop apps only] |
| Namespace | Root\Virtualization\V2 |
| MOF | WindowsVirtualization.V2.mof |
| DLL | Vmms.exe |
See also
Source: Microsoft Learn / Windows Win32 documentation by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.