大网数据广告活动
安装更新与部署

ICEM12

· 52CE 我爱测

ICEM12 verifies that in a ModuleSequence table, standard actions have sequence numbers and custom actions have BaseAction and After values.

ICEM12 verifies that in a ModuleSequence table, standard actions have sequence numbers and custom actions have BaseAction and After values.

This ICEM is available in the Mergemod.cub file provided in the Windows Installer 2.0 SDK and later. For details, see Windows SDK Components for Windows Installer Developers.

Result

ICEM12 posts an error in the following cases:

ICEM12 posts a warning if it finds a custom action that has a Sequence number specified, but no value in the BaseAction or After fields.

Note that all actions found in the CustomAction table are considered custom actions. All other action are considered standard actions.

Example

ICEM12 posts the following error and warning messages for a module that contains the database entries shown below:

Error. Custom actions should use the BaseAction and After fields and not use the 
Sequence field in the Module Sequence tables. The custom action 'Action1' uses the Sequence field 
and does not use the BaseAction and After fields in the ModuleInstallExecuteSequence table. 
    
Error. Custom actions should not leave the Sequence, BaseAction, and After fields 
of the Module Sequence tables all empty. The custom action 'Action3' leaves the Sequence, 
BaseAction, and After fields empty in the ModuleAdminExecuteSequence table.

Error. Standard actions should not use the BaseAction and After fields in Module 
Sequence tables. The standard action 'Action2' has a values entered in the BaseAction 
or After fields of the ModuleAdminExecuteSequence table.

Error. Standard actions must have an entry in the Sequence field of Module Sequence 
tables. The standard action 'Action2' does not have a Sequence value in the 
ModuleExecuteSequence table.

CustomAction

Action Type Source Target
Action1 30 source1 target1
Action3 30 source3 target3

ModuleAdminExecuteSequence

Action Sequence BaseAction After Condition
Action2 Action1 1 true
Action3 true

ModuleInstallExecuteSequence

Action Sequence BaseAction After Condition
Action1 1 true

To fix these errors try the following:

  • Remove the sequence number for the custom action Action1 and use the BaseAction and After fields instead.
  • Enter values into the Sequence, BaseAction, or After fields for the custom action Action3. Leave the BaseAction and After fields empty for standard action Action2.
  • Do not leave the Sequence field empty for standard action Action2.

Related topics

Merge Module ICE Reference

Source: Microsoft Learn / Windows Win32 documentation by Microsoft and contributors. Documentation licensed CC BY 4.0. Code samples are covered by the MIT License. Converted from Markdown, with links normalized and embedded media omitted.

资料来源与适用范围

资料来源
Microsoft Learn / Windows Win32 documentation
适用范围
Windows Win32 API · Source date 05/31/2018